APOPPS™ (& APOPPS-TF™):
patent # 5,728,165
FLO-TECH-TOR™ (& FLO-TECH-TOR-TF™):
patent # 5,571,209

Flexion Contracture Modifications to the FLO-TECH-TOR™

  • The FLO-TECH-TOR™ socket is pre-flexed if the contracture is 30 degrees or more.
  • A hole is drilled in the distal end of the socket.
  • An extra Velcro® compatible Neoprene® band is applied at the knee.
  • The distal end pad(s) are split in the center.
  • A long nylon pull sock is used to facilitate extension of the knee.

Flexion Contracture Protocols

  • The nylon is placed on the patient, extending over the knee, with the long remainder at the distal end.
  • The long remainder of nylon is pulled through the distal end pad(s) and then pushed through the hole in the distal socket.
  • The socket is applied in the usual manner (gently) while the nylon is tugged with a firm yet gentle motion.
  • The long remainder of the pull sock is then reverted on itself and pulled up and over the outside of the FLO-TECH-TOR™.
  • The patient and/or aides must remove the long remainder of the nylon from the outer socket and tug on it every 30 to 40 minutes to encourage extension of the knee and reallocate pressure within the socket for enhanced blood flow.
  • The FLO-TECH-TOR™ must be totally removed 4 to 6 times per day (if two sock protocol is followed) to further stimulate circulation, do range of motion of the knee and check for any folds or wrinkles in the bandages or socks (Range of motion is done along with gentle desensitizing [tissue should not be displaced]).

The FLO-TECH-TOR™ is reapplied 15 to 20 minutes after it is removed.


Printable Flexion Contracture Modifications to the FLO-TECH-TOR™ and Protocol

The link below will launch Adobe Acrobat Reader and enable you to view and print the pages: Follow this link to download Adobe Acrobat Reader (if you do not already have it).

Flexion Contracture Modifications and Protocol - FLO-TECH-TOR™ (pdf file)

Return to Main Protocol Page

 

If you are unable to view the pdf files, please visit the Adobe Web site for a free download of the current version of Adobe Acrobat Reader.

To order pages by mail: 1-800-FLO-TECH (356-8324)

 


| Home | APOPPS™ | APOPPS-TF™ | Custom Orders | Products | Protocols | Discount Programs |
| FAQs | Request Information | Email Us! |

© FLO-TECH® O&P Systems, Inc. 2004, 1- 800-FLO-TECH (356-8324), WWW.1800flo-tech.com